Preview

This is your website preview.

Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.

SANSELINSTRUMENTS 58d0a3098e015309ac46fa7c Products https://www.sansel.co.in
  • 2025-02-01T07:59:16

Humidity sensor calibration chamber The HCAL 1104U is a precision generator of controlled Humidity and Temperature environment inside the chamber. It has huge volume of chamber size to perform a rapid and easy calibration of multiple portable instruments, sensors, transmitter, data logger of different manufacturers. The HCAL 1104U is to generate range from 5°C to 60°C / 3% RH to 95% RH and Psychometric Calculated Dew point indication range from -30°C to 45°C. It has an advantage of external Humidifier for easy maintenance and refilling of water, Semi portable and onsite transportable. The HCAL 1104U working in the principle of mixed flow method for generating the Humidity. A desiccant cell is used to De-Humidify the chamber for low Humidity and Humidifier generates high Humidity. A solid state Peltier element is used for heating and cooling the chamber. The HCAL 1104U improved version has metrology level performance in terms of Control stability and uniformity gradients. Portable Humidity calibrator Hygrometer calibrator Humidity calibration chamber Humidity sensor calibration chamber Precision Humidity generator Precision Humidity and Temperature generator Portable calibration chamber Temperature and Humidity chamber Humidity calibration equipment Humidity and temperature generator

Humidity sensor calibration chamber The HCAL 1104U is a precision generator of controlled Humidity and Temperature environment inside the chamber. It has huge volume of chamber size to perform a rapid and easy calibration of multiple portable instruments, sensors, transmitter, data logger of different manufacturers. The HCAL 1104U is to generate range from 5°C to 60°C / 3% RH to 95% RH and Psychometric Calculated Dew point indication range from -30°C to 45°C. It has an advantage of external Humidifier for easy maintenance and refilling of water, Semi portable and onsite transportable. The HCAL 1104U working in the principle of mixed flow method for generating the Humidity. A desiccant cell is used to De-Humidify the chamber for low Humidity and Humidifier generates high Humidity. A solid state Peltier element is used for heating and cooling the chamber. The HCAL 1104U improved version has metrology level performance in terms of Control stability and uniformity gradients. Portable Humidity calibrator Hygrometer calibrator Humidity calibration chamber Humidity sensor calibration chamber Precision Humidity generator Precision Humidity and Temperature generator Portable calibration chamber Temperature and Humidity chamber Humidity calibration equipment Humidity and temperature generator

  • 2025-02-01T07:59:16

Have any question or need any business consultation?

Have any question or need any business consultation?

Contact Us
Chat with us